1. Stadium lamp
Stadium lamps, also known as sports lighting or floodlights, are powerful and strategically placed lighting fixtures designed to illuminate large outdoor or indoor sports venues, ensuring optimal visibility and safety for athletes and spectators. These high-intensity discharge (HID) lamps, which include metal-halide and high-pressure sodium varieties, are capable of producing a significant amount of light while maintaining energy efficiency. Stadium lamps are typically mounted on tall poles or integrated into the stadium's structure, providing uniform and glare-free illumination across the playing field. Their robust design and ability to withstand harsh weather conditions make them essential for hosting nighttime events, televised matches, and ensuring a vibrant atmosphere at sports facilities around the world.
2. Estándares de pruebas de seguridad en los que nos especializamos
- Prueba de caída;
- Prueba de vibración;
- IEC/TR 62778 blue light hazard;
- IEC/EN 62471 photobiological safety;
- Temperature test, ISTMT;
- Prueba de etiquetado;
- Prueba de continuidad de tierra;
- Prueba de corriente de fuga;
- Humidity test;
- Prueba de resistencia de aislamiento (IR);
- Prueba de resistencia dieléctrica (prueba de Hipot);
- prueba de fallas;
- Creepage distance and clearance measurement;
- Durability test;
- Thermal test;
- Prueba de presión de bola;
- Prueba de llama con aguja;
- Prueba del hilo incandescente;
- Prueba de seguimiento de fugas;
- Prueba de eliminación de manchas;
- Interchangeability of lamp caps and holders;
- Mechanical test;
- Prueba de voltaje de funcionamiento;
- Tumbling barrel test;
- Prueba de estabilidad;
- Water resistance test;
- Rain test;
- Sprinkler test;
- Wind load test for street lamps outdoors;
- …
Product Categories | Estándar IEC | |
Luminarias | General requirements for luminaires | IEC 60598-1 |
Fixed general purpose luminaires | IEC 60598-2-1 | |
Recessed luminaires | IEC 60598-2-2 | |
Luminaries for road and street lighting | IEC 60598-2-3 | |
Portable general purpose luminaires | IEC 60598-2-4 | |
Floodlights | IEC 60598-2-5 | |
Handlamps | IEC 60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | IEC 60598-2-12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | IEC 60598-2-17 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | IEC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | IEC 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | IEC 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | IEC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Europe Standard | |
Luminarias | General requirements for luminaires | EN 60598-1 |
Fixed general purpose luminaires | EN 60598-2-1 | |
Recessed luminaires | EN 60598-2-2 | |
Luminaries for road and street lighting | EN 60598-2-3 | |
Portable general purpose luminaires | EN 60598-2-4 | |
Floodlights | EN 60598-2-5 | |
Handlamps | EN 60598-2-8 | |
Portable luminaires for children | EN 60598-2-10 | |
Aquarium luminaires | EN 60598-2-11 | |
Mains socket-outlet mounted nightlights | EN 60598-2-12 | |
Ground recessed luminaires | EN 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | EN 60598-2-17 | |
Lighting chains | EN 60598-2-20 | |
Rope lights | EN 60598-2-21 | |
Luminaires for emergency lighting | EN 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | EN 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | EN 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | EN 62560 |
Safety and interchangeability requirements for double-capped LED lamps | EN 62776 | |
Modules | General and safety requirements for LED modules | EN 62031 |
Product Categories | United States Standard | |
Luminarias | General requirements for luminaires | UL 1598 |
Fixed general purpose luminaires | UL 1598 | |
Recessed luminaires | UL 1598 | |
Luminaries for road and street lighting | UL 1598 | |
Portable general purpose luminaires | UL 153 | |
Floodlights | UL 153 | |
Handlamps | UL 153 | |
Portable luminaires for children | UL 153 | |
Aquarium luminaires | _ | |
Mains socket-outlet mounted nightlights | UL 1786 | |
Ground recessed luminaires | UL 1598 | |
Luminaires for stage, television, film and photographic studio | UL 1573 | |
Lighting chains | UL 588, UL 2108 | |
Rope lights | UL 588, UL 2108 | |
Luminaires for emergency lighting | UL 924 | |
Controlgear | General and safety requirements for lamp controlgear | UL 8750 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | UL 8750 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | UL 1993 |
Safety and interchangeability requirements for double-capped LED lamps | UL 1993 | |
Modules | General and safety requirements for LED modules | UL 8750 |
Product Categories | Estándar australiano | |
Luminarias | General requirements for luminaires | AN/NZS 60598.1 |
Fixed general purpose luminaires | AN/NZS 60598.2.1 | |
Recessed luminaires | AN/NZS 60598.2.2 | |
Luminaries for road and street lighting | AN/NZS 60598.2.3 | |
Portable general purpose luminaires | AN/NZS 60598.2.4 | |
Floodlights | AN/NZS 60598.2.5 | |
Handlamps | AN/NZS 60598.2.8 | |
Portable luminaires for children | AN/NZS 60598.2.10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | AN/NZS 60598.2.12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | AN/NZS 60598.2.17 | |
Lighting chains | AN/NZS 60598.2.20 | |
Rope lights | AN/NZS 60598.2.21 | |
Luminaires for emergency lighting | AN/NZS 60598.2.22 | |
Controlgear | General and safety requirements for lamp controlgear | AS/NZS 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | AS 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | AS/NZS 62560 |
Safety and interchangeability requirements for double-capped LED lamps | AS/NZS 60598.2.1 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Estándar de Corea del Sur | |
Luminarias | General requirements for luminaires | KC 60598-1 |
Fixed general purpose luminaires | KC 60598-2-1 | |
Recessed luminaires | KC 60598-2-2 | |
Luminaries for road and street lighting | KC 60598-2-3 | |
Portable general purpose luminaires | KC 60598-2-4 | |
Floodlights | KC 60598-2-5 | |
Handlamps | KC 60598-2-8 | |
Portable luminaires for children | KC 60598-2-10 | |
Aquarium luminaires | KC 60598-2-11 | |
Mains socket-outlet mounted nightlights | KC 60598-2-12 | |
Ground recessed luminaires | KC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | KC 60598-2-17 | |
Lighting chains | KC 60598-2-20 | |
Rope lights | KC 60598-2-21 | |
Luminaires for emergency lighting | KC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | KC 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | KC 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | KC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | KC 62776 | |
Modules | General and safety requirements for LED modules | KC 62031 |
Product Categories | Estándar de Japón | |
Luminarias | General requirements for luminaires | J60598-1 |
Fixed general purpose luminaires | J60598-2-1 | |
Recessed luminaires | J60598-2-2 | |
Luminaries for road and street lighting | J60598-2-3 | |
Portable general purpose luminaires | J60598-2-4 | |
Floodlights | J60598-2-5 | |
Handlamps | J60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | J60598-2-11 | |
Mains socket-outlet mounted nightlights | J60598-2-12 | |
Ground recessed luminaires | J60598-2-13 | |
Luminaires for stage, television, film and photographic studio | J60598-2-17 | |
Lighting chains | J60598-2-20 | |
Rope lights | J60598-2-21 | |
Luminaires for emergency lighting | J60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | J61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | J61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | J62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Estándar chino | |
Luminarias | General requirements for luminaires | GB 7000.1 |
Fixed general purpose luminaires | GB 7000.201 | |
Recessed luminaires | GB 7000.202 | |
Luminaries for road and street lighting | GB 7000.203 | |
Portable general purpose luminaires | GB 7000.204 | |
Floodlights | GB 7000.7 | |
Handlamps | GB 7000.208 | |
Portable luminaires for children | GB 7000.4 | |
Aquarium luminaires | GB 7000.211 | |
Mains socket-outlet mounted nightlights | GB 7000.212 | |
Ground recessed luminaires | GB 7000.213 | |
Luminaires for stage, television, film and photographic studio | GB 7000.217 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | GB 7000.2 | |
Controlgear | General and safety requirements for lamp controlgear | GB 19510.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | GB 19510.14 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | GB 24906 |
Safety and interchangeability requirements for double-capped LED lamps | CQC 1106 | |
Modules | General and safety requirements for LED modules | GB 24819 |
3. Safety certifications we specialize in
- Certificación CB;
- Certificación UL;
- Certificación ETL;
- Marca GS;
- Certificación SAA;
- Certificación KC;
- Certificación CCC;
- Certificación CQC;
- Certificación BSMI;
- Certificación PSE;
- …
Para obtener más certificaciones de seguridad, por favor Llene nuestro breve formulario, nuestro experto estará encantado de ayudarle.
4. Visit our safety testing lab
Click the pictures to view more! If you're interested in visiting our safety testing laboratories on site, please Llene nuestro breve formulario¡Estaremos encantados de organizar el hotel y todo!
5. Energy efficiency testing & certifications
- Lamp energy efficiency testing items:
- LM-79 integrating sphere test;
- Photochromic electric parameters;
- LM-80 (lumen maintenance rate) test;
- LM-82 test;
- LM-84 test;
- Spatial photometric distribution test (light distribution curve, beam angle);
- Spatial chromaticity distribution test;
- Light source flicker test;
- Light source starting time and run-up time test;
- TM-21 lifetime projection;
- TM-28 lifetime projection;
- TM-33;
- Aging test;
- EN 62778 assessment of blue light hazard to light sources and luminaires;
- EN 62471 photobiological safety of lamps and lamp systems;
- …
DC or AC Supplied Electronic Control Gear for LED Modules – Performance Requirements:
- GB/T 24825-2009;
- IEC 62384:2020;
- EN IEC 62384:2020;
- BS EN IEC 62384:2020;
Self-Ballasted LED Lamps for General Lighting Services with Supply Voltages >50V – Performance Requirements:
- GB/T 24908-2014;
- IEC 62612:2013+A1:2015+A2:2018;
- EN 62612:2013+A11:2017+A1:2017+A2:2018;
- BS EN 62612:2013+A1:2017+A2:2018;
Luminaire Performance – Part 1 General Requirements:
- GB/T 31897.1-2015;
- IEC 62722-1:2014;
- EN 62722-1:2016;
- BS EN 62722-1:2016;
Luminaire Performance – Part 2-1: Particular Requirements for LED Luminaires:
- GB/T 31897.201-2016;
- IEC 62722-2-1:2014;
- EN 62722-2-1:2016;
- BS EN 62722-2-1:2016;
LED Modules for General Lighting – Performance Requirements:
- GB/T 24823-2017;
- IEC 62717:2014+A1:2015+A2:2019;
- EN 62717:2017+A2:2019;
- BS EN 62717:2017+A2:2019;
Ecodesign Requirements for Light sources and Separate Control Gears Pursuant to Directive 2009/125/EC of the European Parliament (EU) No 2019/2020:
- EU 2019/2020;
Supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with Regard to Energy Labelling of Light Sources:
- EU 2019/2015;
Ecodesign and Energy Labelling Requirements:
- 2021 No.1095;
Approved Method: Electrical and Photometric Measurements of Solid-state Lighting Products:
- IES LM-79-19;
IES Approved Method for Luminous Flux and Color Maintenance of LED Packages, Arrays and Modules:
- ANSI/IES LM-80-15;
Characterization of LED Light Engines and LED Lamps for Electrical and Photometric Properties as a Function of Temperature:
- IES LM-82-12;
Approved Method: Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires:
- IES LM-84-14;
IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers:
- IEEE Standard 1789-2015;
Temporal Light Artifacts: Test Methods and Guidance for Acceptance Criteria:
- NEMA 77-2017;
Projecting Long Term Lumen Maintenance of LED Light Sources:
- IES TM-21-11;
ENERGY STAR Program Requirements Product Specification for Lamps:
- Light Bulbs – Eligibility Criteria Version 2.1;
ENERGY STAR Program Requirements Product Specification for Luminaires:
- Light Fixtures – Eligibility Criteria Version 2.2;
California Code of Regulations Title 20:
- CEC-140-2021-002;
Building Energy Efficiency Standards – Title 24, Part 6, and Associated Administrative Regulations in Part 1:
- CEC-400-2018-021-CMF;
Energy Conservation Program for Consumer Products:
- 10 CFR 430 Appendix BB to Subpart B;
Method for Measuring The Color of Lighting Source:
- GB/T 7922-2008;
General Requirements for Luminaire Distribution Photometric Measurements:
- GB/T 9468-2008;
Performance Requirements of Fixed LED Luminaires for General Lighting:
- GB/T 34446-2017;
Performance Requirements for Recessed LED Luminaires:
- GB/T 30413-2013;
LED Lamps for Road Lighting Performance Specifications:
- GB/T 24907-2010;
Performance Requirements of Portable LED Luminaires for General Lighting:
- GB/T 34452-2017;
Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Of LED Luminaires for Road and Tunnel Lighting:
- GB 37478-2019;
Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Of LED Products for Indoor Lighting:
- GB 30255-2019;
Self-Ballasted LED Reflector Lamps – Performance Requirements:
- GB/T 29296-2012;
Test Methods of Performance of Self-ballasted LED Reflector Lamps:
- GB/T 29295-2012;
Performance Requirements for LED Downlights:
- GB/T 29294-2012;
Measurement Methods of the Performance for LED Downlights:
- GB/T 29293-2012;
Measurement Methods of LED Modules for General Lighting:
- GB/T 24824-2009;
Technical Requirements for Application of LED Indoor Lighting:
- GB/T 31831-2015;
Energy Conservation Certification Criteria for Lighting Products used in Classrooms in Schools and Kindergartens:
- CQC 3155-2016.
- North America: CEC certification, Level VI; DOE certification, Level VI; DLC certification, V5.1; Energy Star® certification, V2.2; NRCan certification, Level IV;
- Unión Europea (UE): ErP certification, Level VI;
- Australia: GEMS certification (formerly MEPS certification), Level VI;
- Corea del Sur: MEPS certification, Level VI;
- Porcelana: CECP certification;
- …
For more energy efficiency certifications, please Llene nuestro breve formulario, nuestro experto estará encantado de ayudarle.
6. Visit our energy efficiency testing lab
Click the pictures to view more! If you're interested in visiting our energy efficiency testing laboratories on site, please Llene nuestro breve formulario¡Estaremos encantados de organizar el hotel y todo!
7. Performance testing
- Salt spray test;
- High temperature storage test;
- High temperature and high humidity test;
- High and low temperature cycling test;
- Lifespan test;
- LCP test;
- Switch test;
- Prueba de vibración;
- IK test;
- Prueba del hilo incandescente;
- Prueba de presión de bola;
- Plastic combustion test;
- Luminaires function test;
- …
8. Visit our performance testing lab
Click the pictures to view more! If you're interested in visiting our performance testing laboratories on site, please Llene nuestro breve formulario¡Estaremos encantados de organizar el hotel y todo!