1. Visit our safety testing labs in Dongguan, China
GTG Group safety testing laboratory for lighting products equipped with state-of-the-art testing equipment and can perform comprehensive safety, performance, mechanical and environmental testing.
2. Meer over het lab
Het is belangrijk op te merken dat de onderstaande lijst niet volledig is. Wil je weten of je product binnen onze testbereik ligt? Alsjeblieft vul ons korte formulier in, onze expert zal u graag verder helpen.
Lichtbron:
- LED -buis;
- Fluorescerende lamp;
- LED -lamp;
Vaste armaturen:
- Plafondlamp;
- Muurlamp;
- Muurwasser;
- Hanger licht;
- Framelamp;
- Bay Light;
- Track licht;
- Straatlicht;
- …
Inbouw armaturen:
- Downlight;
- Paneellicht;
- Spotlicht;
- Ondergrondse lamp;
- Onderwaterlamp;
- Lineair striplicht;
- …
Draagbare armaturen:
- Tafellamp;
- Vloerlamp;
- Handlamp;
- …
Anderen:
- Schijnwerper;
- Noodlamp;
- Nachtlicht;
- Advertentielicht;
- Spiegellicht;
- …
LED -stuurprogramma's:
- Onafhankelijke LED -bestuurder;
- Ingebouwde LED -driver;
- Geïntegreerd LED -stuurprogramma;
- …
LED -modules:
- RGB LED -module;
- LED -module met volledige kleur;
- LED -module met één kleur;
- Dual Color LED -module;
- LED -module met lage spanning;
- Hoogspanning LED -module;
- …
- Valtest;
- Trillingstest;
- IEC/TR 62778 blue light hazard;
- IEC/EN 62471 photobiological safety;
- Temperature test, ISTMT;
- Etiketteringstest;
- Aardcontinuïteitstest;
- Lekstroomtest;
- Humidity test;
- Isolatieweerstandstest (IR);
- Diëlektrische weerstandstest (Hipot-test);
- Fault test;
- Creepage distance and clearance measurement;
- Durability test;
- Thermal test;
- Kogeldruktest;
- Naaldvlamtest;
- Gloeidraadtest;
- Lekkage-opsporingstest;
- Vlekverlichtingstest;
- Interchangeability of lamp caps and holders;
- Mechanical test;
- Bedrijfsspanningstest;
- Tumbling barrel test;
- Stabiliteitstest;
- Water resistance test;
- Rain test;
- Sprinkler test;
- Wind load test for street lamps outdoors;
- …
3. Testing standards we specialize in
Product Categories | IEC-standaard | |
Armaturen | General requirements for luminaires | IEC 60598-1 |
Fixed general purpose luminaires | IEC 60598-2-1 | |
Inbouw armaturen | IEC 60598-2-2 | |
Luminaries for road and street lighting | IEC 60598-2-3 | |
Portable general purpose luminaires | IEC 60598-2-4 | |
Floodlights | IEC 60598-2-5 | |
Handlamps | IEC 60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | IEC 60598-2-12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | IEC 60598-2-17 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | IEC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | IEC 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | IEC 61347-2-13 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | IEC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Europe Standard | |
Armaturen | General requirements for luminaires | EN 60598-1 |
Fixed general purpose luminaires | EN 60598-2-1 | |
Inbouw armaturen | EN 60598-2-2 | |
Luminaries for road and street lighting | EN 60598-2-3 | |
Portable general purpose luminaires | EN 60598-2-4 | |
Floodlights | EN 60598-2-5 | |
Handlamps | EN 60598-2-8 | |
Portable luminaires for children | EN 60598-2-10 | |
Aquarium luminaires | EN 60598-2-11 | |
Mains socket-outlet mounted nightlights | EN 60598-2-12 | |
Ground recessed luminaires | EN 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | EN 60598-2-17 | |
Lighting chains | EN 60598-2-20 | |
Rope lights | EN 60598-2-21 | |
Luminaires for emergency lighting | EN 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | EN 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | EN 61347-2-13 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | EN 62560 |
Safety and interchangeability requirements for double-capped LED lamps | EN 62776 | |
Modules | General and safety requirements for LED modules | EN 62031 |
Product Categories | United States Standard | |
Armaturen | General requirements for luminaires | UL 1598 |
Fixed general purpose luminaires | UL 1598 | |
Inbouw armaturen | UL 1598 | |
Luminaries for road and street lighting | UL 1598 | |
Portable general purpose luminaires | UL 153 | |
Floodlights | UL 153 | |
Handlamps | UL 153 | |
Portable luminaires for children | UL 153 | |
Aquarium luminaires | _ | |
Mains socket-outlet mounted nightlights | UL 1786 | |
Ground recessed luminaires | UL 1598 | |
Luminaires for stage, television, film and photographic studio | UL 1573 | |
Lighting chains | UL 588, UL 2108 | |
Rope lights | UL 588, UL 2108 | |
Luminaires for emergency lighting | UL 924 | |
Controlgear | General and safety requirements for lamp controlgear | UL 8750 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | UL 8750 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | UL 1993 |
Safety and interchangeability requirements for double-capped LED lamps | UL 1993 | |
Modules | General and safety requirements for LED modules | UL 8750 |
Product Categories | Australië standaard | |
Armaturen | General requirements for luminaires | AN/NZS 60598.1 |
Fixed general purpose luminaires | AN/NZS 60598.2.1 | |
Inbouw armaturen | AN/NZS 60598.2.2 | |
Luminaries for road and street lighting | AN/NZS 60598.2.3 | |
Portable general purpose luminaires | AN/NZS 60598.2.4 | |
Floodlights | AN/NZS 60598.2.5 | |
Handlamps | AN/NZS 60598.2.8 | |
Portable luminaires for children | AN/NZS 60598.2.10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | AN/NZS 60598.2.12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | AN/NZS 60598.2.17 | |
Lighting chains | AN/NZS 60598.2.20 | |
Rope lights | AN/NZS 60598.2.21 | |
Luminaires for emergency lighting | AN/NZS 60598.2.22 | |
Controlgear | General and safety requirements for lamp controlgear | AS/NZS 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | AS 61347.2.13 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | AS/NZS 62560 |
Safety and interchangeability requirements for double-capped LED lamps | AS/NZS 60598.2.1 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Zuid-Koreaanse standaard | |
Armaturen | General requirements for luminaires | KC 60598-1 |
Fixed general purpose luminaires | KC 60598-2-1 | |
Inbouw armaturen | KC 60598-2-2 | |
Luminaries for road and street lighting | KC 60598-2-3 | |
Portable general purpose luminaires | KC 60598-2-4 | |
Floodlights | KC 60598-2-5 | |
Handlamps | KC 60598-2-8 | |
Portable luminaires for children | KC 60598-2-10 | |
Aquarium luminaires | KC 60598-2-11 | |
Mains socket-outlet mounted nightlights | KC 60598-2-12 | |
Ground recessed luminaires | KC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | KC 60598-2-17 | |
Lighting chains | KC 60598-2-20 | |
Rope lights | KC 60598-2-21 | |
Luminaires for emergency lighting | KC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | KC 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | KC 61347.2.13 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | KC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | KC 62776 | |
Modules | General and safety requirements for LED modules | KC 62031 |
Product Categories | Japanse standaard | |
Armaturen | General requirements for luminaires | J60598-1 |
Fixed general purpose luminaires | J60598-2-1 | |
Inbouw armaturen | J60598-2-2 | |
Luminaries for road and street lighting | J60598-2-3 | |
Portable general purpose luminaires | J60598-2-4 | |
Floodlights | J60598-2-5 | |
Handlamps | J60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | J60598-2-11 | |
Mains socket-outlet mounted nightlights | J60598-2-12 | |
Ground recessed luminaires | J60598-2-13 | |
Luminaires for stage, television, film and photographic studio | J60598-2-17 | |
Lighting chains | J60598-2-20 | |
Rope lights | J60598-2-21 | |
Luminaires for emergency lighting | J60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | J61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | J61347.2.13 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | J62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Chinese standaard | |
Armaturen | General requirements for luminaires | GB 7000.1 |
Fixed general purpose luminaires | GB 7000.201 | |
Inbouw armaturen | GB 7000.202 | |
Luminaries for road and street lighting | GB 7000.203 | |
Portable general purpose luminaires | GB 7000.204 | |
Floodlights | GB 7000.7 | |
Handlamps | GB 7000.208 | |
Portable luminaires for children | GB 7000.4 | |
Aquarium luminaires | GB 7000.211 | |
Mains socket-outlet mounted nightlights | GB 7000.212 | |
Ground recessed luminaires | GB 7000.213 | |
Luminaires for stage, television, film and photographic studio | GB 7000.217 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | GB 7000.2 | |
Controlgear | General and safety requirements for lamp controlgear | GB 19510.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | GB 19510.14 | |
Lichtbron | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | GB 24906 |
Safety and interchangeability requirements for double-capped LED lamps | CQC 1106 | |
Modules | General and safety requirements for LED modules | GB 24819 |
4. One-stop solution
Door samen te werken met GTG Group, zult u genieten van het gemak van het voltooien van al uw tests (EMC, RF, draadloos, veiligheid, energie -efficiëntie, milieu, duurzaamheid, prestaties, chemische en andere tests) en certificering voor uw product ontvangen van een enkele geaccrediteerde laboratorium. U elimineert ook de hoofdpijn van het gebruik van meerdere laboratoria, vertragingen in logistiek en verzendkosten. Neem vandaag nog contact met ons op!