1. Traffic light
Traffic lights, also known as traffic signals, are automated systems that regulate the flow of vehicular and pedestrian traffic at intersections, crosswalks, and other critical points on roadways. These iconic fixtures consist of a set of colored lights—typically red, yellow, and green—arranged vertically or horizontally, which communicate specific instructions to drivers and pedestrians.
2. सुरक्षा परीक्षण मानक जिनमें हम विशेषज्ञ हैं
- Drop test;
- Vibration test;
- IEC/TR 62778 blue light hazard;
- IEC/EN 62471 photobiological safety;
- Temperature test, ISTMT;
- Labeling test;
- Ground continuity test;
- Leakage current test;
- Humidity test;
- Insulation resistance (IR) test;
- Dielectric withstand test (Hipot test);
- Fault test;
- Creepage distance and clearance measurement;
- Durability test;
- Thermal test;
- Ball pressure test;
- Needle flame test;
- Glow-wire test;
- Leakage tracking test;
- Stain relief test;
- Interchangeability of lamp caps and holders;
- Mechanical test;
- Operating voltage test;
- Tumbling barrel test;
- स्थिरता परीक्षण;
- Water resistance test;
- Rain test;
- Sprinkler test;
- Wind load test for street lamps outdoors;
- …
Product Categories | आईईसी मानक | |
Luminaires | General requirements for luminaires | IEC 60598-1 |
Fixed general purpose luminaires | IEC 60598-2-1 | |
Recessed luminaires | IEC 60598-2-2 | |
Luminaries for road and street lighting | IEC 60598-2-3 | |
Portable general purpose luminaires | IEC 60598-2-4 | |
Floodlights | IEC 60598-2-5 | |
Handlamps | IEC 60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | IEC 60598-2-12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | IEC 60598-2-17 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | IEC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | IEC 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | IEC 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | IEC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Europe Standard | |
Luminaires | General requirements for luminaires | EN 60598-1 |
Fixed general purpose luminaires | EN 60598-2-1 | |
Recessed luminaires | EN 60598-2-2 | |
Luminaries for road and street lighting | EN 60598-2-3 | |
Portable general purpose luminaires | EN 60598-2-4 | |
Floodlights | EN 60598-2-5 | |
Handlamps | EN 60598-2-8 | |
Portable luminaires for children | EN 60598-2-10 | |
Aquarium luminaires | EN 60598-2-11 | |
Mains socket-outlet mounted nightlights | EN 60598-2-12 | |
Ground recessed luminaires | EN 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | EN 60598-2-17 | |
Lighting chains | EN 60598-2-20 | |
Rope lights | EN 60598-2-21 | |
Luminaires for emergency lighting | EN 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | EN 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | EN 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | EN 62560 |
Safety and interchangeability requirements for double-capped LED lamps | EN 62776 | |
Modules | General and safety requirements for LED modules | EN 62031 |
Product Categories | United States Standard | |
Luminaires | General requirements for luminaires | UL 1598 |
Fixed general purpose luminaires | UL 1598 | |
Recessed luminaires | UL 1598 | |
Luminaries for road and street lighting | UL 1598 | |
Portable general purpose luminaires | UL 153 | |
Floodlights | UL 153 | |
Handlamps | UL 153 | |
Portable luminaires for children | UL 153 | |
Aquarium luminaires | _ | |
Mains socket-outlet mounted nightlights | UL 1786 | |
Ground recessed luminaires | UL 1598 | |
Luminaires for stage, television, film and photographic studio | UL 1573 | |
Lighting chains | UL 588, UL 2108 | |
Rope lights | UL 588, UL 2108 | |
Luminaires for emergency lighting | UL 924 | |
Controlgear | General and safety requirements for lamp controlgear | UL 8750 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | UL 8750 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | UL 1993 |
Safety and interchangeability requirements for double-capped LED lamps | UL 1993 | |
Modules | General and safety requirements for LED modules | UL 8750 |
Product Categories | ऑस्ट्रेलिया मानक | |
Luminaires | General requirements for luminaires | AN/NZS 60598.1 |
Fixed general purpose luminaires | AN/NZS 60598.2.1 | |
Recessed luminaires | AN/NZS 60598.2.2 | |
Luminaries for road and street lighting | AN/NZS 60598.2.3 | |
Portable general purpose luminaires | AN/NZS 60598.2.4 | |
Floodlights | AN/NZS 60598.2.5 | |
Handlamps | AN/NZS 60598.2.8 | |
Portable luminaires for children | AN/NZS 60598.2.10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | AN/NZS 60598.2.12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | AN/NZS 60598.2.17 | |
Lighting chains | AN/NZS 60598.2.20 | |
Rope lights | AN/NZS 60598.2.21 | |
Luminaires for emergency lighting | AN/NZS 60598.2.22 | |
Controlgear | General and safety requirements for lamp controlgear | AS/NZS 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | AS 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | AS/NZS 62560 |
Safety and interchangeability requirements for double-capped LED lamps | AS/NZS 60598.2.1 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | दक्षिण कोरिया मानक | |
Luminaires | General requirements for luminaires | KC 60598-1 |
Fixed general purpose luminaires | KC 60598-2-1 | |
Recessed luminaires | KC 60598-2-2 | |
Luminaries for road and street lighting | KC 60598-2-3 | |
Portable general purpose luminaires | KC 60598-2-4 | |
Floodlights | KC 60598-2-5 | |
Handlamps | KC 60598-2-8 | |
Portable luminaires for children | KC 60598-2-10 | |
Aquarium luminaires | KC 60598-2-11 | |
Mains socket-outlet mounted nightlights | KC 60598-2-12 | |
Ground recessed luminaires | KC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | KC 60598-2-17 | |
Lighting chains | KC 60598-2-20 | |
Rope lights | KC 60598-2-21 | |
Luminaires for emergency lighting | KC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | KC 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | KC 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | KC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | KC 62776 | |
Modules | General and safety requirements for LED modules | KC 62031 |
Product Categories | जापान मानक | |
Luminaires | General requirements for luminaires | J60598-1 |
Fixed general purpose luminaires | J60598-2-1 | |
Recessed luminaires | J60598-2-2 | |
Luminaries for road and street lighting | J60598-2-3 | |
Portable general purpose luminaires | J60598-2-4 | |
Floodlights | J60598-2-5 | |
Handlamps | J60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | J60598-2-11 | |
Mains socket-outlet mounted nightlights | J60598-2-12 | |
Ground recessed luminaires | J60598-2-13 | |
Luminaires for stage, television, film and photographic studio | J60598-2-17 | |
Lighting chains | J60598-2-20 | |
Rope lights | J60598-2-21 | |
Luminaires for emergency lighting | J60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | J61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | J61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | J62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | चीन मानक | |
Luminaires | General requirements for luminaires | GB 7000.1 |
Fixed general purpose luminaires | GB 7000.201 | |
Recessed luminaires | GB 7000.202 | |
Luminaries for road and street lighting | GB 7000.203 | |
Portable general purpose luminaires | GB 7000.204 | |
Floodlights | GB 7000.7 | |
Handlamps | GB 7000.208 | |
Portable luminaires for children | GB 7000.4 | |
Aquarium luminaires | GB 7000.211 | |
Mains socket-outlet mounted nightlights | GB 7000.212 | |
Ground recessed luminaires | GB 7000.213 | |
Luminaires for stage, television, film and photographic studio | GB 7000.217 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | GB 7000.2 | |
Controlgear | General and safety requirements for lamp controlgear | GB 19510.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | GB 19510.14 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | GB 24906 |
Safety and interchangeability requirements for double-capped LED lamps | CQC 1106 | |
Modules | General and safety requirements for LED modules | GB 24819 |
3. Safety certifications we specialize in
- सीबी प्रमाणीकरण;
- यूएल प्रमाणीकरण;
- ETL Certification;
- GS Mark;
- SAA Certification;
- KC Certification;
- CCC Certification;
- CQC Certification;
- BSMI Certification;
- PSE Certification;
- …
For more safety certifications, please हमारा संक्षिप्त फॉर्म भरें, हमारे विशेषज्ञ आगे सहायता करने में प्रसन्न होंगे।
4. Visit our safety testing lab
Click the pictures to view more! If you're interested in visiting our safety testing laboratories on site, please हमारा संक्षिप्त फॉर्म भरें, हमें होटल और हर चीज़ की व्यवस्था करने में खुशी होगी!
5. Energy efficiency testing & certifications
- Lamp energy efficiency testing items:
- LM-79 integrating sphere test;
- Photochromic electric parameters;
- LM-80 (lumen maintenance rate) test;
- LM-82 test;
- LM-84 test;
- Spatial photometric distribution test (light distribution curve, beam angle);
- Spatial chromaticity distribution test;
- Light source flicker test;
- Light source starting time and run-up time test;
- TM-21 lifetime projection;
- TM-28 lifetime projection;
- TM-33;
- Aging test;
- EN 62778 assessment of blue light hazard to light sources and luminaires;
- EN 62471 photobiological safety of lamps and lamp systems;
- …
DC or AC Supplied Electronic Control Gear for LED Modules – Performance Requirements:
- GB/T 24825-2009;
- IEC 62384:2020;
- EN IEC 62384:2020;
- BS EN IEC 62384:2020;
Self-Ballasted LED Lamps for General Lighting Services with Supply Voltages >50V – Performance Requirements:
- GB/T 24908-2014;
- IEC 62612:2013+A1:2015+A2:2018;
- EN 62612:2013+A11:2017+A1:2017+A2:2018;
- BS EN 62612:2013+A1:2017+A2:2018;
Luminaire Performance – Part 1 General Requirements:
- GB/T 31897.1-2015;
- IEC 62722-1:2014;
- EN 62722-1:2016;
- BS EN 62722-1:2016;
Luminaire Performance – Part 2-1: Particular Requirements for LED Luminaires:
- GB/T 31897.201-2016;
- IEC 62722-2-1:2014;
- EN 62722-2-1:2016;
- BS EN 62722-2-1:2016;
LED Modules for General Lighting – Performance Requirements:
- GB/T 24823-2017;
- IEC 62717:2014+A1:2015+A2:2019;
- EN 62717:2017+A2:2019;
- BS EN 62717:2017+A2:2019;
Ecodesign Requirements for Light sources and Separate Control Gears Pursuant to Directive 2009/125/EC of the European Parliament (EU) No 2019/2020:
- EU 2019/2020;
Supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with Regard to Energy Labelling of Light Sources:
- EU 2019/2015;
Ecodesign and Energy Labelling Requirements:
- 2021 No.1095;
Approved Method: Electrical and Photometric Measurements of Solid-state Lighting Products:
- IES LM-79-19;
IES Approved Method for Luminous Flux and Color Maintenance of LED Packages, Arrays and Modules:
- ANSI/IES LM-80-15;
Characterization of LED Light Engines and LED Lamps for Electrical and Photometric Properties as a Function of Temperature:
- IES LM-82-12;
Approved Method: Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires:
- IES LM-84-14;
IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers:
- IEEE Standard 1789-2015;
Temporal Light Artifacts: Test Methods and Guidance for Acceptance Criteria:
- NEMA 77-2017;
Projecting Long Term Lumen Maintenance of LED Light Sources:
- IES TM-21-11;
ENERGY STAR Program Requirements Product Specification for Lamps:
- Light Bulbs – Eligibility Criteria Version 2.1;
ENERGY STAR Program Requirements Product Specification for Luminaires:
- Light Fixtures – Eligibility Criteria Version 2.2;
California Code of Regulations Title 20:
- CEC-140-2021-002;
Building Energy Efficiency Standards – Title 24, Part 6, and Associated Administrative Regulations in Part 1:
- CEC-400-2018-021-CMF;
Energy Conservation Program for Consumer Products:
- 10 CFR 430 Appendix BB to Subpart B;
Method for Measuring The Color of Lighting Source:
- GB/T 7922-2008;
General Requirements for Luminaire Distribution Photometric Measurements:
- GB/T 9468-2008;
Performance Requirements of Fixed LED Luminaires for General Lighting:
- GB/T 34446-2017;
Performance Requirements for Recessed LED Luminaires:
- GB/T 30413-2013;
LED Lamps for Road Lighting Performance Specifications:
- GB/T 24907-2010;
Performance Requirements of Portable LED Luminaires for General Lighting:
- GB/T 34452-2017;
Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Of LED Luminaires for Road and Tunnel Lighting:
- GB 37478-2019;
Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Of LED Products for Indoor Lighting:
- GB 30255-2019;
Self-Ballasted LED Reflector Lamps – Performance Requirements:
- GB/T 29296-2012;
Test Methods of Performance of Self-ballasted LED Reflector Lamps:
- GB/T 29295-2012;
Performance Requirements for LED Downlights:
- GB/T 29294-2012;
Measurement Methods of the Performance for LED Downlights:
- GB/T 29293-2012;
Measurement Methods of LED Modules for General Lighting:
- GB/T 24824-2009;
Technical Requirements for Application of LED Indoor Lighting:
- GB/T 31831-2015;
Energy Conservation Certification Criteria for Lighting Products used in Classrooms in Schools and Kindergartens:
- CQC 3155-2016.
- North America: CEC certification, Level VI; DOE certification, Level VI; DLC certification, V5.1; Energy Star® certification, V2.2; NRCan certification, Level IV;
- European Union (EU): ErP certification, Level VI;
- Australia: GEMS certification (formerly MEPS certification), Level VI;
- South Korea: MEPS certification, Level VI;
- चीन: CECP certification;
- …
For more energy efficiency certifications, please हमारा संक्षिप्त फॉर्म भरें, हमारे विशेषज्ञ आगे सहायता करने में प्रसन्न होंगे।
6. Visit our energy efficiency testing lab
Click the pictures to view more! If you're interested in visiting our energy efficiency testing laboratories on site, please हमारा संक्षिप्त फॉर्म भरें, हमें होटल और हर चीज़ की व्यवस्था करने में खुशी होगी!
7. Performance testing
- Salt spray test;
- High temperature storage test;
- High temperature and high humidity test;
- High and low temperature cycling test;
- Lifespan test;
- LCP test;
- Switch test;
- Vibration test;
- IK test;
- Glow-wire test;
- Ball pressure test;
- Plastic combustion test;
- Luminaires function test;
- …
8. Visit our performance testing lab
Click the pictures to view more! If you're interested in visiting our performance testing laboratories on site, please हमारा संक्षिप्त फॉर्म भरें, हमें होटल और हर चीज़ की व्यवस्था करने में खुशी होगी!