1. Lawati makmal ujian keselamatan kami di Dongguan, China
GTG Group safety testing laboratory for lighting products equipped with state-of-the-art testing equipment and can perform comprehensive safety, performance, mechanical and environmental testing.
2. Lebih lanjut mengenai makmal
Adalah penting untuk ambil perhatian bahawa senarai di bawah tidak lengkap. Ingin tahu sama ada produk anda berada dalam skop ujian kami? Tolonglah isi borang ringkas kami, pakar kami akan berbesar hati untuk membantu anda dengan lebih lanjut.
Light Source:
- LED tube;
- Fluorescent lamp;
- LED bulb;
Fixed luminaires:
- Ceiling lamp;
- Wall lamp;
- Wall washer;
- Pendant light;
- Frame lamp;
- Bay light;
- Track light;
- Street light;
- …
Recessed luminaires:
- Downlight;
- Panel light;
- Spot light;
- Underground lamp;
- Underwater lamp;
- Linear strip light;
- …
Portable luminaires:
- Table lamp;
- Floor lamp;
- Handlamp;
- …
Others:
- Floodlight;
- Emergency lamp;
- Night light;
- Advertising light;
- Mirror light;
- …
LED Drivers:
- Independent LED driver;
- Built in LED driver;
- Integrated LED driver;
- …
LED Modules:
- RGB LED module;
- Full color LED module;
- Single color LED module;
- Dual color LED module;
- Low voltage LED module;
- High voltage LED module;
- …
- Ujian jatuh;
- Ujian getaran;
- IEC/TR 62778 blue light hazard;
- IEC/EN 62471 photobiological safety;
- Temperature test, ISTMT;
- Ujian pelabelan;
- Ujian kesinambungan tanah;
- Ujian semasa kebocoran;
- Humidity test;
- Ujian rintangan penebat (IR);
- Ujian tahan dielektrik (ujian Hipot);
- Fault test;
- Creepage distance and clearance measurement;
- Durability test;
- Thermal test;
- Ujian tekanan bola;
- Ujian nyalaan jarum;
- Ujian wayar cahaya;
- Ujian pengesanan kebocoran;
- Ujian pelepasan noda;
- Interchangeability of lamp caps and holders;
- Mechanical test;
- Ujian voltan kendalian;
- Tumbling barrel test;
- Ujian kestabilan;
- Water resistance test;
- Rain test;
- Sprinkler test;
- Wind load test for street lamps outdoors;
- …
3. Testing standards we specialize in
Product Categories | Piawaian IEC | |
Luminair | General requirements for luminaires | IEC 60598-1 |
Fixed general purpose luminaires | IEC 60598-2-1 | |
Recessed luminaires | IEC 60598-2-2 | |
Luminaries for road and street lighting | IEC 60598-2-3 | |
Portable general purpose luminaires | IEC 60598-2-4 | |
Floodlights | IEC 60598-2-5 | |
Handlamps | IEC 60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | IEC 60598-2-12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | IEC 60598-2-17 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | IEC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | IEC 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | IEC 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | IEC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Europe Standard | |
Luminair | General requirements for luminaires | EN 60598-1 |
Fixed general purpose luminaires | EN 60598-2-1 | |
Recessed luminaires | EN 60598-2-2 | |
Luminaries for road and street lighting | EN 60598-2-3 | |
Portable general purpose luminaires | EN 60598-2-4 | |
Floodlights | EN 60598-2-5 | |
Handlamps | EN 60598-2-8 | |
Portable luminaires for children | EN 60598-2-10 | |
Aquarium luminaires | EN 60598-2-11 | |
Mains socket-outlet mounted nightlights | EN 60598-2-12 | |
Ground recessed luminaires | EN 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | EN 60598-2-17 | |
Lighting chains | EN 60598-2-20 | |
Rope lights | EN 60598-2-21 | |
Luminaires for emergency lighting | EN 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | EN 61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | EN 61347-2-13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | EN 62560 |
Safety and interchangeability requirements for double-capped LED lamps | EN 62776 | |
Modules | General and safety requirements for LED modules | EN 62031 |
Product Categories | United States Standard | |
Luminair | General requirements for luminaires | UL 1598 |
Fixed general purpose luminaires | UL 1598 | |
Recessed luminaires | UL 1598 | |
Luminaries for road and street lighting | UL 1598 | |
Portable general purpose luminaires | UL 153 | |
Floodlights | UL 153 | |
Handlamps | UL 153 | |
Portable luminaires for children | UL 153 | |
Aquarium luminaires | _ | |
Mains socket-outlet mounted nightlights | UL 1786 | |
Ground recessed luminaires | UL 1598 | |
Luminaires for stage, television, film and photographic studio | UL 1573 | |
Lighting chains | UL 588, UL 2108 | |
Rope lights | UL 588, UL 2108 | |
Luminaires for emergency lighting | UL 924 | |
Controlgear | General and safety requirements for lamp controlgear | UL 8750 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | UL 8750 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | UL 1993 |
Safety and interchangeability requirements for double-capped LED lamps | UL 1993 | |
Modules | General and safety requirements for LED modules | UL 8750 |
Product Categories | Australia Standard | |
Luminair | General requirements for luminaires | AN/NZS 60598.1 |
Fixed general purpose luminaires | AN/NZS 60598.2.1 | |
Recessed luminaires | AN/NZS 60598.2.2 | |
Luminaries for road and street lighting | AN/NZS 60598.2.3 | |
Portable general purpose luminaires | AN/NZS 60598.2.4 | |
Floodlights | AN/NZS 60598.2.5 | |
Handlamps | AN/NZS 60598.2.8 | |
Portable luminaires for children | AN/NZS 60598.2.10 | |
Aquarium luminaires | IEC 60598-2-11 | |
Mains socket-outlet mounted nightlights | AN/NZS 60598.2.12 | |
Ground recessed luminaires | IEC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | AN/NZS 60598.2.17 | |
Lighting chains | AN/NZS 60598.2.20 | |
Rope lights | AN/NZS 60598.2.21 | |
Luminaires for emergency lighting | AN/NZS 60598.2.22 | |
Controlgear | General and safety requirements for lamp controlgear | AS/NZS 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | AS 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | AS/NZS 62560 |
Safety and interchangeability requirements for double-capped LED lamps | AS/NZS 60598.2.1 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Piawaian Korea Selatan | |
Luminair | General requirements for luminaires | KC 60598-1 |
Fixed general purpose luminaires | KC 60598-2-1 | |
Recessed luminaires | KC 60598-2-2 | |
Luminaries for road and street lighting | KC 60598-2-3 | |
Portable general purpose luminaires | KC 60598-2-4 | |
Floodlights | KC 60598-2-5 | |
Handlamps | KC 60598-2-8 | |
Portable luminaires for children | KC 60598-2-10 | |
Aquarium luminaires | KC 60598-2-11 | |
Mains socket-outlet mounted nightlights | KC 60598-2-12 | |
Ground recessed luminaires | KC 60598-2-13 | |
Luminaires for stage, television, film and photographic studio | KC 60598-2-17 | |
Lighting chains | KC 60598-2-20 | |
Rope lights | KC 60598-2-21 | |
Luminaires for emergency lighting | KC 60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | KC 61347.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | KC 61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | KC 62560 |
Safety and interchangeability requirements for double-capped LED lamps | KC 62776 | |
Modules | General and safety requirements for LED modules | KC 62031 |
Product Categories | Piawaian Jepun | |
Luminair | General requirements for luminaires | J60598-1 |
Fixed general purpose luminaires | J60598-2-1 | |
Recessed luminaires | J60598-2-2 | |
Luminaries for road and street lighting | J60598-2-3 | |
Portable general purpose luminaires | J60598-2-4 | |
Floodlights | J60598-2-5 | |
Handlamps | J60598-2-8 | |
Portable luminaires for children | IEC 60598-2-10 | |
Aquarium luminaires | J60598-2-11 | |
Mains socket-outlet mounted nightlights | J60598-2-12 | |
Ground recessed luminaires | J60598-2-13 | |
Luminaires for stage, television, film and photographic studio | J60598-2-17 | |
Lighting chains | J60598-2-20 | |
Rope lights | J60598-2-21 | |
Luminaires for emergency lighting | J60598-2-22 | |
Controlgear | General and safety requirements for lamp controlgear | J61347-1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | J61347.2.13 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | J62560 |
Safety and interchangeability requirements for double-capped LED lamps | IEC 62776 | |
Modules | General and safety requirements for LED modules | IEC 62031 |
Product Categories | Piawaian China | |
Luminair | General requirements for luminaires | GB 7000.1 |
Fixed general purpose luminaires | GB 7000.201 | |
Recessed luminaires | GB 7000.202 | |
Luminaries for road and street lighting | GB 7000.203 | |
Portable general purpose luminaires | GB 7000.204 | |
Floodlights | GB 7000.7 | |
Handlamps | GB 7000.208 | |
Portable luminaires for children | GB 7000.4 | |
Aquarium luminaires | GB 7000.211 | |
Mains socket-outlet mounted nightlights | GB 7000.212 | |
Ground recessed luminaires | GB 7000.213 | |
Luminaires for stage, television, film and photographic studio | GB 7000.217 | |
Lighting chains | IEC 60598-2-20 | |
Rope lights | IEC 60598-2-21 | |
Luminaires for emergency lighting | GB 7000.2 | |
Controlgear | General and safety requirements for lamp controlgear | GB 19510.1 |
Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | GB 19510.14 | |
Light Source | Safety and interchangeability requirements for self-ballasted LED-lamps for general lighting services by voltage > 50 V | GB 24906 |
Safety and interchangeability requirements for double-capped LED lamps | CQC 1106 | |
Modules | General and safety requirements for LED modules | GB 24819 |
4. One-stop solution
Dengan bekerja dengan Kumpulan GTG, anda akan menikmati kemudahan untuk melengkapkan semua ujian anda (EMC, RF, wayarles, keselamatan, kecekapan tenaga, alam sekitar, ketahanan, prestasi, kimia dan ujian lain) dan menerima pensijilan untuk produk anda daripada satu yang diiktiraf. makmal. Anda juga akan menghapuskan sakit kepala menggunakan pelbagai makmal, kelewatan dalam logistik dan kos penghantaran. Hubungi kami hari ini!